You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
35 lines
1.4 KiB
35 lines
1.4 KiB
---
|
|
title: "Coax Cables"
|
|
summary: A quick comparison of the three coax types that I use.
|
|
date: 2024-03-02T09:55:35+01:00
|
|
lastmod: 2024-09-28T23:48:06+0000
|
|
|
|
showBreadcrumbs: true
|
|
showReadingTime: false
|
|
showWordCount: false
|
|
---
|
|
|
|
## Comparison
|
|
|
|
| Name | ∅ \[mm\] | Impedance \[Ω\] | Lenght \[m\] | Loss \[dB\] | Loss/100m \[dB\] | Weight/m \[kg\] |
|
|
| :----- | -------: | --------------: | -----------: | ----------: | ---------------: | --------------: |
|
|
| H-155 | 5.50 | 50.44 | 10.18 | 0.329 | 3.232 | 0.38 |
|
|
| RG-174 | 2.79 | 50.70 | 6.03 | 0.775 | 12.850 | 0.01 |
|
|
| RG-316 | 2.59 | 49.45 | 5.15 | 0.568 | 11.025 | 0.01 |
|
|
|
|
Measurements have been made with a NanoVNA-H (HW version 3.4) version 1.2.19 (Build time: Jan 31 2023 - 16:06:06)
|
|
at 14.020 MHz (because that is around the frequency that I use mainly at my home QTH).
|
|
|
|
## What cable to use?
|
|
|
|
I usually use the H-155 at home because the 10m are a good fit from my
|
|
terrace to the table in the living room and it has the least loss and
|
|
weight is not a factor when deploying at home.
|
|
|
|
For portable operation I use the RG-316 because it is very leightweight
|
|
and is "not so lossy" than the RG-174.
|
|
|
|
I'd take the RG-174 when I'm not sure about what lenght the antenna cable
|
|
should be because I have two cables with 6m with the appropriate connectors
|
|
already on the cables.
|